Category 6 cable
Category 6 cable, commonly referred to as Cat 6, is a cable standard for Gigabit Ethernet and other network physical layers that is backward compatible with the Category 5/5e and Category 3 cable standards. Compared with Cat 5 and Cat 5e, Cat 6 features more stringent specifications for crosstalk and system noise. The cable standard provides performance of up to 250 MHz and is suitable for 10BASE-T, 100BASE-TX (Fast Ethernet), 1000BASE-T/1000BASE-TX (Gigabit Ethernet) and 10GBASE-T (10-Gigabit Ethernet).
Whereas Category 6 cable has a reduced maximum length when used for 10GBASE-T; Category 6a cable, or Augmented Category 6, is characterized to 500 MHz and has improved alien crosstalk characteristics, allowing 10GBASE-T to be run for the same distance as previous protocols.
Category 6
Like most earlier cables, Category 6 cable contains four twisted wire pairs. Although it is sometimes made with 23 AWG wire, the increase in performance with Cat 6 comes mainly from better insulation; 22 to 24 AWG copper is allowed if the ANSI/TIA-568-B.2-1 performance specifications are met. Cat 6 patch cables are normally terminated in 8P8C modular connectors. Attenuation, near end crosstalk (NEXT), and PSNEXT (power sum NEXT) in Cat 6 cable and connectors are all significantly lower than Cat 5 or Cat 5e, which also uses 24 AWG wire.
The heavier insulation in some Cat 6 cables makes them too thick to attach to 8P8C connectors without a special modular piece, resulting in a technically out-of-compliance assembly.[citation needed]
Connectors use either T568A or T568B pin assignments; the choice is arbitrary provided both ends of a cable are the same.
If Cat 6 rated patch cables, jacks, and connectors are not used with Cat 6 wiring, overall performance is degraded to that of the cable or connector.
Because the conductor sizes are generally the same, Cat 6 jacks may also be used with Cat 5e cable.
Category 6 cable can be identified by the printing on the side of the cable sheath
Note: This is from left to right, with the (plastic) tab faced away from you.
Pins on 8P8C plug face
Category 6a
The latest standard from the TIA for enhanced performance standards for twisted pair cable systems was defined in February 2008 in ANSI/TIA/EIA-568-B.2-10. Category 6a (or Augmented Category 6) is defined at frequencies up to 500 MHz—twice that of Cat. 6.
Category 6a performs at improved specifications, in particular in the area of alien crosstalk as compared to Cat 6 UTP, which exhibited high alien noise in high frequencies.
The global cabling standard ISO/IEC 11801 has been extended by the addition of amendment 2. This amendment defines new specifications for Cat. 6A components and Class EA permanent links. These new global Cat. 6A/Class EA specifications require a new generation of connecting hardware offering far superior performance compared to the existing products that are based on the American TIA standard.[2]
The most important point is a performance difference between ISO/IEC and EIA/TIA component specifications for the NEXT transmission parameter. At a frequency of 500 MHz, an ISO/IEC Cat., 6A connector performs 3 dB better than a Cat. 6A connector that conforms with the EIA/TIA specification. 3 dB equals 100% increase of near-end crosstalk noise reduction when measured in absolute magnitudes; see 3dB-point.[2]
Confusion therefore arises because of the different naming conventions and performance benchmarks laid down by the International ISO/IEC and American TIA/EIA standards, which in turn are different from the regional European standard, EN 50173-1. In broad terms, the ISO standard for Cat6A is the highest, followed by the European standard and then the American
Maximum length
When used for 10/100/1000BASE-T, the maximum allowed length of a Cat 6 cable is 100 meters (330 ft). This consists of 90 meters (300 ft) of solid "horizontal" cabling between the patch panel and the wall jack, plus 10 meters (33 ft) of stranded patch cable between each jack and the attached device. Since stranded cable has higher attenuation than solid cable, exceeding 10 metres of patch cabling will reduce the permissible length of horizontal cable.
When used for 10GBASE-T, Cat 6 cable's maximum length is 55 meters (180 ft) in a favourable alien crosstalk environment, but only 37 meters (121 ft) in a hostile alien crosstalk environment, such as when many cables are bundled together. However, because the effects of alien crosstalk environments on cables are difficult to determine prior to installation, it is highly recommended that all Cat6 cables being used for 10GBASE-T are electrically tested once installed. Because it would take much work to test every cable in the field, and because of the risk of having a nonworking installed cable, one should use Cat6A cable in all 10GBASE-T applications. Cat6A does not need to be tested after installation. Cat6A does not have this limitation and can run 10GBASE-T at 100 meters (330 ft).
Installation caveats
Category 6 and 6a cable must be properly installed and terminated to meet specifications. The cable must not be kinked or bent too tightly (the bend radius should be at least 4 times the outer diameter of the cable[5]). The wire pairs must not be untwisted and the outer jacket must not be stripped back more than 1/2 inch (1.27 cm).
All shielded cables must be grounded for safety and effectiveness. A continuous shield connection maintained from end to end.[6] Ground loops develop when there is more than one ground connection and the difference in common mode voltage potential at these ground connections introduces noise into the cabling.[7]